产品简介
The Modular Switched POPS CDU Provides a complete power distribution system for high density cabinets. Two vertical power strips with mixed outlets are combined with a horizontal Control Module. The Control Module provides network connectivity, environmental monitoring, and digital current displays for load balancing. The controller mounts in the U-space of the equipment rack. Redundant power supplied from each CDU means that no separate power cord is necessary. Network connectivity is maintained even if one of the power inputs to cabinet is lost.
In addition to inlet monitoring this Cabinet Distribution Unit provides network and serial-based power management and alerting capabilities for each outlet with the ability to monitor:
Current Load (A)
Voltage (V)
Power (W)
Apparent Power(VA)
Crest Factor and
Power Factor
Utilizing our grouping feature, power information is available per device (multiple outlets), groups of devices (applications), individual Cabinet PDU, cabinet, rows of cabinets or the whole Data Center Floor. Combine the Sentry POPS Smart Cabinet CDU with the Sentry Power Manager (SPM) software tool to cluster outlets and gain power usage information across multiple Cabinet PDU's individual IP address.
The Sentry Power Manager (SPM) provides power distribution unit power (kW and kW-h) monitoring and environmental monitoring across all Sentry CDU's within the network. Reboot a single or dual-power supply server with one command. Receive email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Only the Sentry Power Manager is capable of regulating all Sentry Cabinet PDU's across the network while providing power readings and management at an outlet level.
产品特点
Sentry Cabinet PDU Specifications | |||||
Item # | Available Input Voltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
BDL-CXG36V Modular PDU - 3Ph 50/60A | |||||
BDL-CXG36VDX-01 | 240V, 3-Phase Delta 50/60Hz | 60 A | (2) IEC Blue 9hr 3P+G Plugs, 10'(3m) Bottom Cord Entry | (24) IEC 60320/C13 (12) IEC 60320/C19 per each CDU | See Data Sheet |
BDL-CXG36VDV-01 | 240V, 3-Phase Delta 50/60Hz | 50 A | (2) CS8365 plugs, 10'(3m) Bottom Cord Entry | (24) IEC 60320/C13 (12) IEC 60320/C19 per each CDU | See Data Sheet |
BDL-CXG36VYY-01 | 208V 3-Phase Wye, 50/60Hz | 60 A | (2) IEC Blue 9hr 3P+N+G Plugs, 10'(3m) Bottom Cord Entry | (24) IEC 60320/C13 (12) IEC 60320/C19 per each CDU | See Data Sheet |
How to order: > Select a model from the list above. > Verify mounting of CDU and location of the horizontal Control Module within the rack. > (2) DIN power cables are needed per installation. The DIN connector is located opposite the input power cord on the CDU. Select a cable length from the list below. (2) CAB-1504A - 2'(0.6m) DIN Power Cable (2) CAB-1504C - 10'(3m) DIN Power Cable (used when CDU is invert and connector is at bottom of rack) | |||||
Additional Features and Specifications | |||||
Standards |