产品详情
CWG-8H2C413

产品简介

The Switched CDU's combine remote conguration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP-based alerts and email alerts when power or environmental conditions exceed thresholds. Assign users access rights to designated outlets or groups. Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

产品特点

Sentry Cabinet PDU Specifications
Item #Available Input
Voltages
Rated AmperageAvailable Input CordOutletsDimensions
(L x W x D)
CWG-8H2 208V and 230V 20/30A, 16/32A Breakers
CWG-8H2A413
CXG-8H2A413*
200-240V
50/60Hz
20A (cTUVus Mark)
16A (T Mark)
IEC 60320/C20 Power Inlet(8) IEC 60320/C131.75 x 17.2 x 7.1 in.
(44 x 437 x 181 mm)
CWG-8H2C413
CXG-8H2C413*
208-240V
50/60Hz
30ANEMA L6-30P
Cordset, 10 ft (3m)
(8) IEC 60320/C131.75 x 17.2 x 7.1 in.
(44 x 437 x 181 mm)
CWG-8HEK413
CXG-8HEK413*
230V
50/60Hz
32AIEC 60309
Cordset, 10 ft (3m)
(8) IEC 60320/C131.75 x 17.2 x 7.1 in.
(44 x 437 x 181 mm)
* CXG refers to the Expansion Module
Additional Features and Specifications
Standards
> cTUVus Mark to UL 60950-1 : 2007 and CAN/CSA 22.2 No. 60950-1-07
> TUV T-Mark to EN 60950-1 : 2006 + A11
> EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
> FCC Class A, Part 15
> CE Mark
> RoHS/WEEE

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2 and v3
> SSHv2
> Telnet
> LDAPv3
> LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)
> IPv4 and v6

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Optional Temperature & Humidity Probe
-EMTH-1-1 Temperature & Humidity Probe, 10ft (3m)
> Environmental Monitor
- EMCU-1-1B allows up to (2) additional temperature &
humidity probes, (1) water sensor, (4) dry contact
closures, (1) analog-to-digital contact sensor. Includes (1)
temperature/humidity probe with unit.
> SPM (Sentry Power Manager) Appliance:
- Monitor and Manage multiple Sentry CDU's
- Monitor and Manage all alarm conditions
- Reporting and Trending
- Group or Cluster outlets for reboot and power
information
> SPM (Sentry Power Manager):
- Monitor and Manage multiple Sentry CDU's
- Monitor and Manage all alarm conditions
- Reporting and Trending
- Group or Cluster outlets for reboot and power
information
- Optional Appliance or virtual version
- SPM v5.1+ is VMware READY

Power Cord Options
> PTCORD-L1 IEC 60320/C19 - NEMA L6-20P , 10ft (3m)
> PTCORD-L2 IEC 60320/C19 - Schuko 10ft (3m)
> PTCORD-L3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10ft (3m)
> PTCORD-L4 IEC 60320/C19 - BS1363 13A (UK) 10ft (3m)