产品详情
CL-24V1-C20M

产品简介

The Smart Cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.

Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU.The Sentry Cabinet PDU product family uniquely meets these demands.

The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the Cabinet PDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.

The Cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements. Each branch circuit utilizes a Bussman® SC fuse as an Overcurrent Protection Device (OCPD).Now you can safely run 30-amp power drops to your server cabinet where individual outlet receptacles have lower output ratings (i.e., 20-amps).

230 V products include a EN 60950-1:2001 certification.

产品特点


Sentry  Cabinet PDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)***
CS-24V
CS-24V1-C20M
CL-24V1-C20M
100-120V
50/60Hz
20AIEC 60320/C20
Power Inlet
(24) NEMA 5-20R69"x1.75"x2.25"
(1752x44.4x57mm)
CS-24V1-L30M
CL-24V1-L30M
100-120V
50/60Hz
30ANEMA L5-30P
Cord Set, 10 ft (3m)
(24) NEMA 5-20R69"x1.75"x2.25"
(1752x44.4x57mm)
**CL refers to the Expansion Module
***Please note that the depth of these enclosures are 3.00" deep at the placement for the fuse retractors
Power Cord Options
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10'
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10'
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10'
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
Additional Features and Specifications
Standards
> cTUVus - UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUVGS - EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
   - EMCU-1-1 add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and
     1 water sensor port