产品详情
CL-24VDD311

产品简介

The Smart Cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.

Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU.The Sentry Cabinet PDU product family uniquely meets these demands.

The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the Cabinet PDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.

The Cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements. Each branch circuit utilizes a Bussman® SC fuse as an Overcurrent Protection Device (OCPD).Now you can safely run 30-amp power drops to your server cabinet where individual outlet receptacles have lower output ratings (i.e., 20-amps).

产品特点


Sentry Cabinet PDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)**
CS-24VDD311
CS-24VDD311
CL-24VDD311*
208-240V, 3-phase Delta
50/60Hz
20A
NEMA L15-20P
10ft (3m), Front Cord
(24) IEC 60320/C1369"x1.75"x2.25"
(1752x44.4x57mm)
CS-24VDD313
CL-24VDD313*
208-240V, 3-phase Delta
50/60Hz
20ANEMA L15-20P
10ft (3m), Bottom Cord
(24) IEC 60320/C1369"x1.75"x2.25"
(1752x44.4x57mm)
CS-24VD-L30M
CL-24VD-L30M*
208-240V, 3-phase Delta
50/60Hz
30ANEMA L15-30P
10ft (3m), Front Cord
(24) IEC 60320/C1369"x1.75"x2.25"
(1752x44.4x57mm)
CS-24VDE313
CL-24VDE313*
208-240V, 3-phase Delta
50/60Hz
30ANEMA L15-30P
10ft (3m), Bottom Cord
(24) IEC 60320/C1369"x1.75"x2.25"
(1752x44.4x57mm)
CS-24VYL311
CL-24VYL311*
120/208V, 3-phase Wye
50/60Hz
20ANEMA L21-20P
10ft (3m), Front Cord
(24) IEC 60320/C13
(1) NEMA 5-20R
69"x1.75"x2.25"
(1752x44.4x57mm)
CS-24VYL313
CL-24VYL313*
120/208V, 3-phase Wye
50/60Hz
20ANEMA L21-20P
10ft (3m), Bottom Cord
(24) IEC 60320/C13
(1) NEMA 5-20R
69"x1.75"x2.25"
(1752x44.4x57mm)
CS-24VY-L30M
CL-24VY-L30M*
120/208V, 3-phase Wye
50/60Hz
30ANEMA L21-30P
10ft (3m), Front Cord
(24) IEC 60320/C13
(1) NEMA 5-20R
69"x1.75"x2.25"
(1752x44.4x57mm)
CS-24VYM313
CL-24VYM313*
120/208V, 3-phase Wye
50/60Hz
30ANEMA L21-30P
10ft (3m), Bottom Cord
(24) IEC 60320/C13
(1) NEMA 5-20R
69"x1.75"x2.25"
(1752x44.4x57mm)
* CL refers to the Expansion Module
**Please note that the depth of these enclosures are 3.0" deep at the placement of the fuse retractors
Additional Features and Specifications
Standards
> cTUVus  UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUVGS  EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
>Optional Temperature & Humidity Probe
- EMTH-1-1 Temperature & Humidity Probe, 10ft (3m)
> Environmental Monitor
- EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit.
>SPM (Sentry Power Manager) Appliance:
- Monitor and Manage multiple Sentry CDU's
- Monitor and Manage all alarm conditions
- Reporting and Trending