产品简介
The Smart Cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.
Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU.The Sentry Cabinet PDU product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the Cabinet PDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.
The Cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements. Each branch circuit utilizes a Bussman® SC fuse as an Overcurrent Protection Device (OCPD).Now you can safely run 30-amp power drops to your server cabinet where individual outlet receptacles have lower output ratings (i.e., 20-amps).
产品特点
Sentry Cabinet PDU Specifications | |||||
Item # | Available Input Voltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D)** |
CS-24VDD311 | |||||
CS-24VDD311 CL-24VDD311* | 208-240V, 3-phase Delta 50/60Hz | 20A | NEMA L15-20P 10ft (3m), Front Cord | (24) IEC 60320/C13 | 69"x1.75"x2.25" (1752x44.4x57mm) |
CS-24VDD313 CL-24VDD313* | 208-240V, 3-phase Delta 50/60Hz | 20A | NEMA L15-20P 10ft (3m), Bottom Cord | (24) IEC 60320/C13 | 69"x1.75"x2.25" (1752x44.4x57mm) |
CS-24VD-L30M CL-24VD-L30M* | 208-240V, 3-phase Delta 50/60Hz | 30A | NEMA L15-30P 10ft (3m), Front Cord | (24) IEC 60320/C13 | 69"x1.75"x2.25" (1752x44.4x57mm) |
CS-24VDE313 CL-24VDE313* | 208-240V, 3-phase Delta 50/60Hz | 30A | NEMA L15-30P 10ft (3m), Bottom Cord | (24) IEC 60320/C13 | 69"x1.75"x2.25" (1752x44.4x57mm) |
CS-24VYL311 CL-24VYL311* | 120/208V, 3-phase Wye 50/60Hz | 20A | NEMA L21-20P 10ft (3m), Front Cord | (24) IEC 60320/C13 (1) NEMA 5-20R | 69"x1.75"x2.25" (1752x44.4x57mm) |
CS-24VYL313 CL-24VYL313* | 120/208V, 3-phase Wye 50/60Hz | 20A | NEMA L21-20P 10ft (3m), Bottom Cord | (24) IEC 60320/C13 (1) NEMA 5-20R | 69"x1.75"x2.25" (1752x44.4x57mm) |
CS-24VY-L30M CL-24VY-L30M* | 120/208V, 3-phase Wye 50/60Hz | 30A | NEMA L21-30P 10ft (3m), Front Cord | (24) IEC 60320/C13 (1) NEMA 5-20R | 69"x1.75"x2.25" (1752x44.4x57mm) |
CS-24VYM313 CL-24VYM313* | 120/208V, 3-phase Wye 50/60Hz | 30A | NEMA L21-30P 10ft (3m), Bottom Cord | (24) IEC 60320/C13 (1) NEMA 5-20R | 69"x1.75"x2.25" (1752x44.4x57mm) |
* CL refers to the Expansion Module **Please note that the depth of these enclosures are 3.0" deep at the placement of the fuse retractors | |||||
Additional Features and Specifications | |||||
Standards > cTUVus UL 60950-1-2003 > CAN/CSA 22.2 No. 60950-1:2003 > TUVGS EN 60950-1:2001 > FCC Class A, Part 15 > CE > EMC-EN 55022 Class A, EN 55024 Communications > 10/100 BaseT Ethernet > HTTP/HTTPS > SSLv3/TLSv1 > SNMPv2 > SSHv2 > Telnet > LDAPv3/LDAPS > TACACS+ > RADIUS > RS-232 (Serial) Branch Circuit Protection > Compliant to UL 60950-1 Accessories >Optional Temperature & Humidity Probe - EMTH-1-1 Temperature & Humidity Probe, 10ft (3m) > Environmental Monitor - EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit. >SPM (Sentry Power Manager) Appliance: - Monitor and Manage multiple Sentry CDU's - Monitor and Manage all alarm conditions - Reporting and Trending |