产品简介
Designed for extremely high power usage the CS-24V4 (400V 63A), the Smart Cabinet PDU delivers reliable power distribution, local
power monitoring via LEDs, power monitoring via IP and enviornmental (temperature & humidity) monitoring via IP.
This Sentry PIPS CDU combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.
Combine the Sentry PIPS Smart Cabinet PDU with the Sentry Power Manager (SPM) software tool to gain power usage information across multiple Cabinet PDU's individual IP address.
This Smart cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.
Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU. The Sentry cabinet PDU product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (cabinet PDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the cabinet PDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.
The cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements.
产品特点
Sentry Cabinet PDU Specifications | |||||
Item # | Available InputVoltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
CS-24V4 400V 3Ph 63A with PIPS | |||||
CS-24V47458A3 CL-24V47458A3* | 3-Phase Wye, 230/400V50/60Hz | 63A | IEC Red 6hr 3P+N+G Plug, 10'(3m), Top Cord Entry | (24) IEC 60320/C19 | 1905 x 44 x 89 mm (75.0 x 1.75 x 3.50 in.) |
*CL refers to the Expansion Module | |||||
Additional Features and Specifications | |||||
Standards > European Union (TUVGS Mark) to EN 60950-1: 2006 + A11 > FCC Class A, Part 15 > CE Mark > EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A Communications > 10/100 BaseT Ethernet > HTTP/HTTPS > SSLv3/TLSv1 > SNMPv2 and v3 > SSHv2 > Telnet > LDAPv3/LDAPS > TACACS+ > RADIUS > RS-232 (Serial) > IPv4 and v6 Branch Circuit Protection > Compliant to UL 60905-1 > 10 KAIC Circuit Breakers Accessories > EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m) > EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit. > Sentry Power Manager (SPM) |