产品简介
The Server Technology Smart CDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides highly-accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Smart “Master" CDU can be connected to the Smart “Link" CDU to extend the network access to the redundant or secondary power feed.
HDOT
The highest possible outlet density available in a network connected PDU. Up to 42 C13's in a 42U high by 1U wide device. Additional features include high native cord retention that eliminates the need for custom and costly ancillary locking cord devices. Manufactured with robust high temperature materials carrying a UL94 V-0 ame rating makes these outlets ideally suited for harsh data center environments.
产品特点
Sentry CDU Specifications | |||||
Item # | Available Input Voltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
CS39CS-5 415V 3-Phase 20/30A with PIPS | |||||
CS39CS-5BKE2S222 CL39CS-5BKE2S222* | 220-240V L-N Nominal,50/60Hz | ≤16A (20 peak) | NEMA L22-20P, 10ft,5-C, 12AWG | (33) IEC 60320/C13 (6) IEC 60320/C19 | 70.1 x 1.75 x 2.25 in. (3" deep at breakers) |
CS39CS-5CKE2S222 CL39CS-5CKE2S222* | 220-240V L-N Nominal,50/60Hz | ≤24A (30 peak) | NEMA L22-30P, 10ft,5-C, 10AWG | (33) IEC 60320/C13 (6) IEC 60320/C19 | 70.1 x 1.75 x 2.25 in. (3" deep at breakers) |
CS39CS-5NKE2S222 CL39CS-5NKE2S222* | 220-240V L-N Nominal,50/60Hz | ≤16A (20 peak) | IEC 60309 6hr 3P+N+PE Red,10ft, 5-C, 12AWG | (33) IEC 60320/C13 (6) IEC 60320/C19 | 70.1 x 1.75 x 2.25 in. (3" deep at breakers) |
CS39CS-5PKE2S222 CL39CS-5PKE2S222* | 220-240V L-N Nominal,50/60Hz | ≤24A (30 peak) | IEC 60309 6hr 3P+N+PE Red,10ft, 5-C, 10AWG | (33) IEC 60320/C13 (6) IEC 60320/C19 | 70.1 x 1.75 x 2.25 in. (3" deep at breakers) |
* CL part numbers refer to the Expansion CDU | |||||
Additional Features and Specifications | |||||
Standards • cTUVus Mark to UL 60950-1:2007 and CAN/CSA 22.2 No. 60950-1-07 • EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A • FCC Class A, Part 15 • RoHS/WEEE Communications • 10/100 Mbps Ethernet (RJ-45 connector) • RS-232 serial (RJ-45 connector) • Two (2) temperature/humidity sensor inputs (4P4C) • Link port (RJ-12) • Web-browser GUI and command-line-interface (CLI) HTTP/HTTPS, SSLv3/TLSv1, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS Branch Circuit Protection • UL489 compliant circuit breakers, 1-pole, 20A • Six (6) branches • Current Rating: ≤ 16A • Voltage Rating: 220V-240V nominal, 50/60Hz Accessories • EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m) • EMCU-1-1B Environmental Monitor adding: -Two (2) EMTH-1-1 temperature/humidity ports (one probe included) -One (1) EMWS-1-1 water sensor port (probe sold separately) -Four (4) dry contact (NO/NC) monitoring points -One (1) 8-bit analog-to-digital converter (0 to 5VDC) • SPM (Sentry Power Manager): -Monitor and manage multiple PDUs from a single point -Monitor and manage alarm conditions -Create reports and trends on stored data -Analyze power usage per phase -Optional appliance or virtual version -VMware Ready • Device / Output Locking Power Cords -Multiple options available -Contact Server Technology for details. • Mounting Brackets -Buttons (KIT-0020) included for tool-less mounting. |