产品简介
Designed for high density 1U server installations the CS-42V provides forty-two C13 outlets. The Smart Cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and enviornmental (temperature & humidity) monitoring via IP.
Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU. The Sentry Cabinet PDU product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the Cabinet PDUs True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.
The Cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements.
产品特点
Sentry Cabinet PDU Specifications | |||||
Item # | Available InputVoltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
CS-42VD/VY 50/60A 3Ph | |||||
CS-42VDX4111 CL-42VDX411* | 240V, 3-Phase Delta50/60Hz | 60A | IEC Blue 9hr 3P+G Plug, 10'(3m), Bottom/Frt Cord | (42) IEC 60320/C13 | 76.0 x 1.75 x 3.50 in. (1930 x 44 x 89 mm) |
CS-42VDV4111 CL-42VDV411* | 240V, 3-Phase Delta50/60Hz | 50A | CS8365C Plug, 10'(3m), Bottom/Frt Cord | (42) IEC 60320/C13 | 76.0 x 1.75 x 3.50 in. (1930 x 44 x 89 mm) |
CS-42VYY4111 CL-42VYY411* | 208V, 3-Phase Wye50/60Hz | 60A | IEC Blue 9hr 3P+N+G Plug, 10'(3m), Bottom/Frt Cord | (42) IEC 60320/C13 | 76.0 x 1.75 x 3.50 in. (1930 x 44 x 89 mm) |
*CL refers to the Expansion Module | |||||
Additional Features and Specifications | |||||
Standards > cTUVus – UL 60950-1-2003 > CAN/CSA 22.2 No. 60950-1:2003 > FCC Class A, Part 15 > CE > EMC-EN 55022 Class A, EN 55024 Communications > 10/100 BaseT Ethernet > HTTP/HTTPS > SSLv3/TLSv1 > SNMPv2 > SSHv2 > Telnet > LDAPv3/LDAPS > TACACS+ > RADIUS > RS-232 (Serial) Branch Circuit Protection > Compliant to UL 60905-1 Accessories > EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m) > EMCU-1-1B allows up to (2) additional temperature & humidity probes, (1) water sensor, (4) dry contact closures, (1) analog-to-digital contact sensor. Includes (1) temperature/humidity probe with unit. > Sentry Power Manager (SPM) |