产品简介
This Sentry PIPS CDU combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.
Combine the Sentry PIPS Smart Cabinet PDU with the Sentry Power Manager (SPM) software tool to gain power usage information across multiple Cabinet PDU's individual IP address.
This Smart cabinet PDU delivers reliable power distribution, local power monitoring via LEDs, power monitoring via IP and environmental (temperature & humidity) monitoring via IP.
Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU.The Sentry cabinet PDU product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (cabinet PDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the cabinet PDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.
The cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements.产品特点
Sentry CDU Specifications | |||||
Item # | Available Input Voltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
PIPS CS-48VD-3Ph | |||||
CS-48VDX458A11 CL-48VDX458A1* | 3-Phase Delta, 208 V50/60Hz | 60A | IEC 60309 60A Cordset, 10ft (3m) | (36) IEC 60320/C13 (12) IEC 60320/C19 | 69.0 x 3.5 x 3.5 in. (1752 x 89 x 89 mm) |
CS-48VDV458A11 CL-48VDV458A1* | 3-Phase Delta, 208 V50/60Hz | 50A | CS8365C Cordset, 10ft (3m) | (36) IEC 60320/C13 (12) IEC 60320/C19 | 69.0 x 3.5 x 3.5 in. (1752 x 89 x 89 mm) |
CS-48VYY458A11 CL-48VYY458A1* | 3-Phase Wye, 208 V50/60Hz | 60A | IEC 60309 60A Cordset, 10ft (3m) | (36) IEC 60320/C13 (12) IEC 60320/C19 | 69.0 x 3.5 x 3.5 in. (1752 x 89 x 89 mm) |
Additional Features and Specifications | |||||
Standards > US & Canada (cTUVus Mark) to UL 60950-1: 2007 and CAN/CSA 22.2 No. 60950-1-07 > 10/100 BaseT Ethernet > HTTP/HTTPS > SSLv3/TLSv1 > SNMPv2 and v3 > SSHv2 > Telnet > LDAPv3 and LDAPS > TACACS+ > RADIUS > RS-232 (Serial) > IPv4 and v6 Branch Circuit Protection > Compliant to UL 60950-1 Accessories > Temperature & Humidity Probe - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m) - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and 1 water sensor port |