The Switched Cabinet PDU 8H2 combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Its horizontal configuration offers the perfect solution for small or cramped cabinets where one or two vertical power distribution units will not fit.
This Sentry PIPS CDU combines all of the features of a Switched CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy.

Only the Switched Cabinet PDU products provide the flexibility needed for all datacenters and remote sites; including support for 20-amp or 30-amp power input; 208-240V or European 230V configuration; UL 60950-1 branch circuit protection; EN 60950-1:2001, SSL & SSH security; and SNMP-based input current monitoring. For cabinets with low-density servers, this cabinet distribution unit delivers unparalleled solutions.

产品特点

Sentry  Cabinet PDU Specifications
Item #Available Input
Voltages
Rated AmperageAvailable Input CordOutletsDimensions
(L x W x D)
CW-8H2
CW-8H2A413
CX-8H2A413*
200-240V
50/60Hz
20A (cTUVus Mark)
16A (T Mark)
IEC 60320/C20
Power Inlet
(8) IEC 60320/C131.75" x 17.0" x 7.0"
(44x431.8x177.8mm)
CW-8H2C413
CX-8H2C413*
208-240V
50/60Hz
30ANEMA L6-30P
Cord Set, 10 ft (3m)
(8) IEC 60320/C131.75" x 17.0" x 7.0"
(44x431.8x177.8mm)
CW-8HEK413
CX-8HEK413*
230V
50/60Hz
32AIEC 60309
Cord Set, 10 ft (3m)
(8) IEC 60320/C131.75" x 17.0" x 7.0"
(44x431.8x177.8mm)
* CX refers to the Expansion Module
Power Cord Options
> PTCORD-L1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10'(3m)
> PTCORD-L2 IEC 60320/C19 - Schuko 10'(3m)
> PTCORD-L3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10'(3m)
> PTCORD-L4 IEC 60320/C19 - BS1363 13A (UK) 10'(3m)
Additional Features and Specifications
Standards
> cTUVus Mark to UL 60950-1: 2007 and CAN/CSA 22.2 No. 60950-1-07
> TUV T-Mark to EN 60950-1: 2006 + A11
> EMC to EN 55022 Class A, EN 55024, CISPR 22 Class A
> FCC Class A, Part 15
> CE Mark
> RoHS/WEEE

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2c & v3
> SSHv2
> Telnet
> LDAPS/LDAPv3
> TACACS+
> RADIUS
> RS-232 (Serial)
> IPv4 & v6

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
Optional Accessories
> EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m)
> EMCU-1-1B Environmental Monitor adding
  - Two (2) EMTH-1-1 Temperature/Humidity Probes (one  included)
  - One (1) EMWS-1-1 Water Sensor (sold separately)
  - Four (4) Dry Contact (NO/NC) monitoring points
  - One (1) 8-bit analog-to-digital converter (0 to 5VDC)
> SPM (Sentry Power Manager)
  - Monitor and manage multiple PDUs from a single point
  - Monitor and manage alarm conditions
  - Create reports and trends on stored data
  - Control and analyze power usage per power supply and device
  - Optional appliance or virtual version
  - VMware READY