产品详情
CW-16HDEK454

产品简介

The Switched Cabinet CDU CW-16HD2/E provides configuration and management over a power distribution unit remotely.  In addition, this units provides power monitoring and environmental monitoring. The GUI interface provides the ability to reboot single or dual-power servers with one command. SNMP alerts can be set up in the event power or environmental conditions exceed specified thresholds and user specific access rights can be assigned to designated outlets or groups.

This Sentry PIPS CDU provides the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy.

This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.

Combine the Sentry PIPS Switched Cabinet PDU with the Sentry Power Manager software tool to gain power usage information across multiple Cabinet PDU's individual IP address.

The Switched Cabinet CDU products provide the flexibility needed for all data centers and remote sites; including support for 20-amp or 30-amp power input; 208-240V or 230V configurations; UL 60950-1 branch circuit protection; EN 60950-1:2001, SSL & SSH security; and SNMP-based input current monitoring. For cabinets with mid-density servers, this cabinet distribution unit delivers unparalleled remote management solutions.

产品特点

Sentry  Cabinet PDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)
CW-16HD2/E with PIPS
CW-16HD2A454
CX-16HD2A454*
208-240V
50/60Hz
20A(2) IEC C20 Power Inlets(16) IEC 60320/C133.50 x 17.20 x 10.00 in.
(89 x 437 x 254 mm)
CW-16HD2C454
CX-16HD2C454*
208-240V
50/60Hz
30A(2) NEMA L6-30P Plugs, 10'(3m) Cord(16) IEC 60320/C133.50 x 17.20 x 10.00 in.
(89 x 437 x 254 mm)
CW-16HDEA454
CX-16HDEA454*
230V
50/60 Hz
16A(2) IEC C20 Power Inlets(16) IEC 60320/C133.50 x 17.20 x 10.00 in.
(89 x 437 x 254 mm)
CW-16HDEK454
CX-16HDEK454*
230V
50/60 Hz
32A(2) IEC Blue 2P+G Plug, 10'(3m) Cord(16) IEC 60320/C133.50 x 17.20 x 10.00 in.
(89 x 437 x 254 mm)
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10?
> PTCORD-2 IEC 60320/C19 - Schuko 10?
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10?
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10?
Additional Features and Specifications
Standards
> cTUVus ? UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUVGS ? EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC-EN 55022 Class A, EN 55024

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
   - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and
     1 water sensor port