产品简介

This Sentry PIPSTM CDUTM combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.

Also included in this unit, the Sentry POPS (Per Outlet Power Sensing)Switched CWG-24V2/VE 1Ph 20/30A CDUTM is a mixed outlet Cabinet Power Distribution Unit with the network and serial-based power monitoring and alerting capabilities of the Smart Cabinet CDU plus the ability to monitor:

Current Load (A)
Voltage (V)
Power (W)
Apparent Power(VA)
Crest Factor and
Power Factor

Utilizing our grouping feature, power information is available per device (multiple outlets), groups of devices (applications), individual Cabinet CDU, cabinet, rows of cabinets or the whole Data Center Floor. Combine the Sentry POPS Switched Cabinet CDU with the Sentry Power Manager (SPM) software tool to cluster outlets and gain power usage information across multiple Cabinet CDU's individual IP address.

The Sentry Power Manager (SPM) provides power distribution unit power (kW and kW-h) monitoring and environmental monitoring across all Sentry CDU's within the network.  Reboot a single or dual-power supply server with one command.  Receive email alerts when power or environmental conditions exceed thresholds.  Assign users specific access rights to designated outlets or groups.  Only the Sentry Power Manager is capable of regulating all Sentry Cabinet PDU's across the network while providing power readings and management at an outlet level.

Business Initiatives
POPS and Sentry Power Manager can be used to address the following business initiatives for the Data Center Operations Staff and Management:

How much power is our IT equipment using?
• Power information displayed for equipment per individual outlet includes current, voltage, power (kW), apparent power, crest factor and power factor.
• Outlets can be grouped and clustered together from a single Cabinet PDU to an expansion unit, across Data Centers, Cities, Countries and Continents; as long as the Sentry Power Manager has the Cabinet PDU's discovered into the system. Outlet grouping and clustering allows for control as well as aggregate (kW and kW-h) power readings.

What is our Power Usage Effectiveness?

• IT equipment power information generated from Sentry Power Manager (SPM) can be used to calculate PUE and DCIE efficiency ratings from the Green Grid.

How can determining the Power Usage Effectiveness benefit our company?

• PUE and DCiE efficiency a metrics provides the ability to determine how changes affect efficiency to monitor changes in the data center.
• Reduce energy and save
PG&E's demand response programs offer incentives for business owners who curtail their facility's energy use during times of peak demand. Find out how your business can benefit and help make a difference in the state's energy well being.

How do I identify underutilized and comatose servers as candidates for virtualization or shutdown?

• Outlet utilization is indicated via three reports including: Zero Power Report, Low Power Report and High Power Report.

- Zero Power Report identifies outlets that are switched on but not drawing any power.  
- Low Power Report identifies underutilized and comatose servers that could be candidates for virtualization or to be shut down.  This report indicates equipment operating under a user defined power threshold.
- High Power Report identifies equipment operating above a user defined power threshold.

How do I implement Power Billing for individual departments or at a co-location facility?
• Outlet clustering can be utilized to show an aggregate power reading for these clusters.
• kW and kW-hour power information that can be utilized for billing, power monitoring, trending and power reports.

How will the Sentry Power Manager interact with my current Building Management System?

• Power and other information can be exported to a Building Management System (BMS) via the ODBC compliant database.

How do I access the power information from a Sentry CDU?

• SPM constantly polls Sentry Cabinet PDUs for power, outlet status and environmental conditions.
• SPM also is an SNMP trap destination for alerts and alarms.

How do I control equipment all on a per outlet basis?

• A Global view and access to Sentry Cabinet PDUs from one central appliance.
• SPM permits users with proper access rights to control individual, groups or clusters of outlets.

What other capabilities can I utilize via the Sentry Power Manager (SPM) and POPS units?

• Configure conditions for alarm notification.
• View devices based on temperature, humidity, current and status conditions dictated within the software.

*Note, The SPM software provides information in terms of power consumption which can be utilized to calculate efficiencies and, in some cases, qualify for incentives and rebates from local energy companies.  Talk to your local provider to find out more regarding their energy rebate and incentive programs.

产品特点

Sentry Cabinet PDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)
CWG-24V2/VE (C13/C19) with PIPS
CWG-24V2A415C1
CXG-24V2A415C1*
208-240 V
50/60Hz
20AIEC C20 Inlet, Bottom/Frt Entry(18) IEC 60320/C13
(6) IEC 60320/C19
64.0 x 1.75 x 3.50 in.
(1625 x 44 x 89 mm)
CWG-24V2C415C1
CXG-24V2C415C1*
208-240 V
50/60Hz
30ANEMA L6-30P Plug, 10'(3m), Bottom/Frt Cord(18) IEC 60320/C13
(6) IEC 60320/C19
64.0 x 1.75 x 3.50 in.
(1625 x 44 x 89 mm)
CWG-24VEA415C1
CXG-24VEA415C1*
230V
50/60Hz
16AIEC C20 Inlet, Bottom/Frt Entry(18) IEC 60320/C13
(6) IEC 60320/C19
64.0 x 1.75 x 3.50 in.
(1625 x 44 x 89 mm)
CWG-24VEK415C1
CXG-24VEK415C1*
230V
50/60Hz
32AIEC Blue 2P+G Plug, 10'(3m), Bottom/Frt Cord(18) IEC 60320/C13
(6) IEC 60320/C19
64.0 x 1.75 x 3.50 in.
(1625 x 44 x 89 mm)
* CXG refers to the Expansion Module
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10' (3m)
> PTCORD-2 IEC 60320/C19 - Schuko 10'(3m)
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10'(3m)
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10'(3m)
Additional Features and Specifications
Standards
> cTUVus – UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUVGS – EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC-EN 55022 Class A, EN 55024, CISPR 22 Class A

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
   - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and
     1 water sensor port