产品简介
This Sentry PIPS(TM) CDU(TM) combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.
Also included in this unit, the Sentry POPS (Per Outlet Power Sensing) Switched CWG-16V2/VE CDU(TM) is a mixed outlet Cabinet Power Distribution Unit with the network and serial-based power monitoring and alerting capabilities of the Switched Cabinet CDU plus the ability to monitor:
Current Load (A)
Voltage (V)
Power (W)
Apparent Power(VA)
Crest Factor and
Power Factor
Utilizing our grouping feature, power information is available per device (multiple outlets), groups of devices (applications), individual Cabinet PDU, cabinet, rows of cabinets or the whole Data Center Floor. Combine the Sentry POPS Switched Cabinet PDU with the Sentry Power Manager (SPM) software tool to cluster outlets and gain power usage information across multiple Cabinet PDU's individual IP address.
The Sentry Power Manager (SPM) provides power distribution unit power (kW and kW-h) monitoring and environmental monitoring across all Sentry CDU's within the network. Reboot a single or dual-power supply server with one command. Receive email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Only the Sentry Power Manager is capable of regulating all Sentry Cabinet PDU's across the network while providing power readings and management at an outlet level.
产品特点
Sentry Cabinet PDU Specifications | |||||
Item # | Available Input Voltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
CWG-16V(C13-C19) | |||||
CWG-16V2A317A1 CXG-16V2A317A1* | 208-240V 50/60Hz | 20A | IEC C20 Inlet, Bottom Entry | (12) IEC 60320/C13 (4) IEC 60320/C19 | 49.4x1.75x3.50 in. (1256x44x89 mm) |
CWG-16V2C317A1 CXG-16V2C317A1* | 208-240V 50/60Hz | 30A | NEMA L6-30P Plug, 10'(3m), Bottom Cord | (12) IEC 60320/C13 (4) IEC 60320/C19 | 49.4x1.75x3.50 in. (1256x44x89 mm) |
CWG-16VEA317A1 CXG-16VEA317A1* | 230V 50/60Hz | 16A | IEC C20 Inlet, Bottom Entry | (12) IEC 60320/C13 (4) IEC 60320/C19 | 49.4x1.75x3.50 in. (1256x44x89 mm) |
CWG-16VEK317A1 CXG-16VEK317A1* | 230V 50/60Hz | 32A | IEC Blue 2P+G Plug, 10'(3m), Bottom Cord | (12) IEC 60320/C13 (4) IEC 60320/C19 | 49.4x1.75x3.50 in. (1256x44x89 mm) |
* CXG refers to the Expansion Module | |||||
Power Cord Options | |||||
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10' > PTCORD-2 IEC 60320/C19 - Schuko 10' > PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10' > PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10' | |||||
Additional Features and Specifications | |||||
Standards > cTUVus - UL 60950-1-2003 > CAN/CSA 22.2 No. 60950-1:2003 > TUVGS - EN 60950-1:2001 > FCC Class A, Part 15 > CE > EMC-EN 55022 Class A, EN 55024, CISPR 22 Class A Communications > 10/100 BaseT Ethernet > HTTP/HTTPS > SSLv3/TLSv1 > SNMPv2 > SSHv2 > Telnet > LDAPv3/LDAPS > TACACS+ > RADIUS > RS-232 (Serial) Branch Circuit Protection > Compliant to UL 60950-1 Accessories > Temperature & Humidity Probe - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m) - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and 1 water sensor port |