产品详情
CWG-24VEA458

产品简介

This Sentry PIPSTM CDUTM combines all of the features of a Smart CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.

Also included in this unit, the Sentry POPS (Per Outlet Power Sensing)Switched CWG-24V2/VE 1Ph 20/30A CDUTM is a 24 C13 Cabinet Power Distribution Unit with the network and serial-based power monitoring and alerting capabilities of the Smart Cabinet CDU plus the ability to monitor:

Current Load (A)
Voltage (V)
Power (W)
Apparent Power(VA)
Crest Factor and
Power Factor

Utilizing our grouping feature, power information is available per device (multiple outlets), groups of devices (applications), individual Cabinet CDU, cabinet, rows of cabinets or the whole Data Center Floor. Combine the Sentry POPS Switched Cabinet CDU with the Sentry Power Manager (SPM) software tool to cluster outlets and gain power usage information across multiple Cabinet CDU's individual IP address.

The Sentry Power Manager (SPM) provides power distribution unit power (kW and kW-h) monitoring and environmental monitoring across all Sentry CDU's within the network.  Reboot a single or dual-power supply server with one command.  Receive email alerts when power or environmental conditions exceed thresholds.  Assign users specific access rights to designated outlets or groups.  Only the Sentry Power Manager is capable of regulating all Sentry Cabinet PDU's across the network while providing power readings and management at an outlet level.

产品特点

Sentry Cabinet PDU Specifications
Item #Available Input
Voltages

Rated

Amperage

Available Input CordOutletsDimensions
(L x W x D)
CWG-24V2/VE (24xC13) with PIPS
CWG-24V2A458
CXG-24V2A458*
208-240 V
50/60Hz
20AIEC C20 Inlet, Top Cord Entry(24) IEC 60320/C1369.0 x 1.75 x 3.50 in.
(1753 x 44 x 89 mm)
CWG-24V2C458
CXG-24V2C458*
208-240 V
50/60Hz
30ANEMA L6-30P Plug, 10' (3m), Top Cord Entry(24) IEC 60320/C1369.0 x 1.75 x 3.50 in.
(1753 x 44 x 89 mm)
CWG-24VEA458
CXG-24VEA458*
230V
50/60Hz
16AIEC C20 Inlet, Top Cord Entry(24) IEC 60320/C1369.0 x 1.75 x 3.50 in.
(1753 x 44 x 89 mm)
CWG-24VEK458
CXG-24VEK458*
230V
50/60Hz
32AIEC Blue 2P+G Plug, 10'(3m), Top Cord Entry(24) IEC 60320/C1369.0 x 1.75 x 3.50 in.
(1753 x 44 x 89 mm)
* CXG refers to the Expansion Module
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10? (3m)
> PTCORD-2 IEC 60320/C19 - Schuko 10?(3m)
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10?(3m)
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10?(3m)
Additional Features and Specifications
Standards
> US & Canada (cTUVus Mark) to UL 60950-1: 2007 and CAN/CSA 22.2 No. 60950-1-07
> European Union (TUVGS Mark) to EN 60950-1: 2006+A11
> FCC Class A, Part 15
> EMC to EN 55022 Class A, CISPR 22 Class A
> CE

Communications
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2/v3
> SSHv2
> Telnet
> LDAPv3/LDAPS
> TACACS+
> RADIUS
> RS-232 (Serial)
> IPv6

Branch Circuit Protection
> Compliant to UL 60950-1

Accessories
> Temperature & Humidity Probe
   - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m)
   - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and
     1 water sensor port